DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MCX18N00A View Datasheet(PDF) - Sony Semiconductor

Part Name
Description
Manufacturer
MCX18N00A
Sony
Sony Semiconductor Sony
MCX18N00A Datasheet PDF : 19 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MCX18N00A/MCX18N00B
Image Sensor Characteristics Measurement Method
Measurement conditions
(1) In the following measurements, each supply voltage is at the typical values.
(2) In the following measurements, spot blemishes are excluded and, unless otherwise specified, the optical
black level (OB) is used as the reference for the signal output, which is taken as the value of Y signal
output of the measurement system.
Definition of Standard Imaging Conditions
1) Standard imaging condition I: Use a pattern box (luminance 706cd/m2, color temperature of 3200K halogen
source) as a subject. (Pattern for evaluation is not applicable.) Use a ND2 filter and image at F5.6 or
equivalent. The luminous intensity to the sensor receiving surface at this point is defined as the standard
sensitivity testing luminous intensity.
2) Standard imaging condition II: Image a light source with a uniformity of brightness within 2% at all angles
(color temperature of 3200K).
1. Sensitivity
Set to standard imaging condition I. After selecting the electronic shutter mode with a shutter speed of
1/250s, measure the Y signal (Ys) at the center of the screen and substitute the values into the following
formula.
S = Ys ×
250
60
[mV]
2. Saturation signal
Set to standard imaging condition II. After adjusting the luminous intensity to 10 times the intensity applying
with an average value of Y signal output, 200mV, measure the minimum value of the Y signal.
3. Smear
Set to standard imaging condition II. With using ND2 filter and the lens diaphragm at F5.6 or equivalent,
adjust the luminous intensity to 500 times the intensity applying with an average value of Y signal output,
200mV. When the readout clock is stopped and the charge drain is executed by the electronic shutter at
the respective H blankings, measure the maximum value YSm [mV] of the Y signal output, and substitute
the values into the following formula.
Sm = YSm × 1 × 1 × 100 [%] (1/10V method conversion value)
200 500 10
4. Dark signal
Measure the average value of the Y signal output (Ydt [mV]) with the device ambient temperature of 60°C
and the device in the light-obstructed state, using the horizontal idle transfer level as a reference.
5. Dark signal shading
After measuring 4, measure the maximum (Ydmax [mV]) and minimum (Ydmin [mV]) values of the Y signal
output, and substitute the values into the following formula.
Ydt = Ydmax – Ydmin [mV]
–9–