A17201
Two-Wire AC-Coupled Differential Sensor IC
with Integrated Filter Capacitor
OPERATING CHARACTERISTICS: Valid throughout full operating and temperature ranges, unless otherwise noted
Characteristics
Symbol
Test Conditions
Min.
Typ. [1]
Max.
ELECTRICAL CHARACTERISTICS
Supply Voltage [2]
Reverse Supply Current [3]
Supply Zener Current
Supply Zener Clamp Voltage
Supply Current
RESPONSE CHARACTERISTICS
VCC
IRCC
IZSUPPLY
VZSUPPLY
ICC(LOW)
ICC(HIGH)
Operating, TJ < TJ(MAX)
VCC = –18 V
VCC = 28 V
ICC = ICC(MAX) + 3 mA, TA = 25°C
Low-current state
High-current state
3.5
12
24
–
–
–1
–
–
19
28
33
37
3
–
7
12.0
–
16.0
Power-On Time [4][5]
Settling Time [5][6]
Response Time [5]
Upper Corner Frequency [7]
Lower Corner Frequency [7]
OUTPUT CHARACTERISTICS [8]
tPO
tSETTLING
tRESPONSE
fCU
fCL
VCC > VCC(MIN)
fBdiff ≥ 100 Hz
Equal to tPO + tSETTLING; fBdiff ≥ 100 Hz
–3 dB, single pole
–3 dB, single pole
–
7
15
–
–
310
–
–
325
20
–
–
–
–
8
Output Slew Rate Time
dI/dt No load (UA package only)
7
–
–
Output Rise Time
Output Fall Time
MAGNETIC CHARACTERISTICS
tr
ΔI/Δt from 10% to 90% ICC level; corresponds to
measured output slew rate with CSUPPLY
–
tf
ΔI/Δt from 90% to 10% ICC; corresponds to
measured output slew rate with CSUPPLY
–
–
1.5
–
1.5
Operate Point [9]
Release Point [8]
Hysteresis [8]
Applied Magnetic Field [10]
BOP
BRP
BHYS
Bdiff
Bdiff increasing, fBdiff = 200 Hz,
Bdiff = 50 Gp-p,
ICC switches from low to high
Bdiff decreasing, fBdiff = 200 Hz,
Bdiff = 50 Gp-p,
ICC switches from high to low
fBdiff = 200 Hz, Bdiff = 50 Gp-p
Differential p-p magnetic field
–
7
17.4
–17.4
–7
–
–
14
–
–
–
1250
Unit
V
mA
mA
V
mA
mA
ms
ms
ms
kHz
Hz
mA/μs
μs
μs
G
G
G
G
[1] Typical values are at TA = 25°C and VCC = 12 V. Performance may vary for individual units, within the specified maximum and minimum limits.
[2] Maximum voltage must be adjusted for power dissipation and junction temperature; see Power Derating section.
[3] Negative current is defined as conventional current coming out of (sourced from) the specified device terminal.
[4] Time required to initialize device.
[5] See Definitions of Terms section.
[6] Time required for the output switchpoints to be within specification.
[7] The specification is based on statistical evaluation of a limited sample population.
[8] Load circuit is RL = 100 Ω and CL = 10 pF. Pulse duration measured at threshold of ((ICC(HIGH) + ICC(LOW)) / 2).
[9] For lower frequencies, the absolute values of BOP, BRP, and BHYS may decrease due to delay induced by the high-pass filter.
[10] Exceeding the maximum magnetic field may result in compromised absolute accuracy.
4
Allegro MicroSystems
955 Perimeter Road
Manchester, NH 03103-3353 U.S.A.
www.allegromicro.com