A17201
Two-Wire AC-Coupled Differential Sensor IC
with Integrated Filter Capacitor
DEFINITION OF TERMS
The following provides additional information about some of the
parameters cited. For additional information, visit the Allegro
website at www.allegromicro.com.
Applied Magnetic Field, Bdiff – The differential magnetic flux
density, which is calculated as the arithmetic difference of the
flux densities observed by each of the two Hall elements. fBdiff is
the input signal frequency.
Output Off Switchpoint (Operate Point), BOP – The value
of increasing differential magnetic flux density at which the out-
put signal, ICC switches from ICC(LOW) to ICC(HIGH).
Output On Switchpoint (Release Point), BRP – The value
of decreasing differential magnetic flux density at which the
output signal, ICC from ICC(HIGH) to ICC(LOW).
Power-On Time, tPO – The time needed by the device, after
power is applied, to initialize all circuitry necessary for proper
operation.
Settling Time, tSETTLING – The time required by the device,
after tPO, and after a valid magnetic signal has been applied, to
provide proper output transitions. Settling time is a function of
magnetic offset, offset polarity, signal phase, signal frequency,
and signal amplitude.
Response Time, tRESPONSE – The total time required for
generating zero-crossing output transitions after initialization (the
sum of Power-On Time and Settling Time).