11223344556677889900112233445566778899001122334455667788990011221122334455667788990011223344556677889900112233445566778899001122112233445566P7788r99e0011c22i33s44i55o6677n889980011-22C3344h5566,77D889900if11f2211. 2243344-55C6677h8899,0011122733V445566A778899n00a1122l33o44g556677M889900u11l22t11i22p3344l55e66x7788e99r0011s22
RON
VIN
RS
CCOM(ON)
CL
VS
Figure 10. Equivalent model of one multiplexer channel
The table below shows how many time constants (mτ) are
needed to reach an accuracy of one LSB. τ = RON x CCOM(ON)
Bits Accuracy (%) m
8
0.25
6
12
0.012
9
15
0.0017
11
Now, lets calculate what the maximum sampling rate for the
PS398. Assume a 12-bit accuracy and room temperature
operation.
In equation (1) above, n = 8, tTRANS = 150ns, tSETTLING = 9τ,
τ = 100Ω x 54pF
fS =
__________1_____________ ,
8 [150ns + 9(100Ω x 54pF)]
or fS = 630kHz.
Assuming a x4 oversampling rate, the maximum sampling speed
for the PS398 would be 630÷4 = 157kHz.