DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX5387 Просмотр технического описания (PDF) - Maxim Integrated

Номер в каталоге
Компоненты Описание
производитель
MAX5387 Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Dual, 256-Tap, Volatile, Low-Voltage
Linear Taper Digital Potentiometer
Note 5: Drive HA with a 1kHz GND to VDD amplitude tone. LA = LB = GND. No load. WB is at midscale with a 10pF load.
Measure WB.
Note 6: The wiper settling time is the worst-case 0 to 50% rise time, measured between tap 0 and tap 127. H_ = VDD, L_ = GND,
and the wiper terminal is loaded with 10pF capacitance to ground.
Note 7: Digital timing is guaranteed by design and characterization, not production tested.
Note 8: The SCL clock period includes rise and fall times (tR = tF). All digital input signals are specified with tR = tF = 2ns and
timed from a voltage level of (VIL + VIH)/2.
H
N.C.
W
W
L
L
Figure 1. Voltage-Divider and Variable Resistor Configurations
(VDD = 5V, TA = +25°C, unless otherwise noted.)
Typical Operating Characteristics
SUPPLY CURRENT vs. TEMPERATURE
1.0
0.9
0.8
0.7
VDD = 5V
0.6
0.5
0.4
VDD = 2.6V
0.3
0.2
0.1
0
-40 -25 -10 5 20 35 50 65 80 95 110 125
TEMPERATURE (°C)
RESISTANCE (W-TO-L)
vs. TAP POSITION (10kI)
11
10
9
8
7
6
5
4
3
2
1
0
0
51 102 153 204 255
TAP POSITION
10,000
SUPPLY CURRENT
vs. DIGITAL INPUT VOLTAGE
1000
VDD = 5V
100
VDD = 2.6V
10
1
0.1
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
DIGITAL INPUT VOLTAGE (V)
RESISTANCE (W-TO-L)
vs. TAP POSITION (50kI)
55
50
45
40
35
30
25
20
15
10
5
0
0
51 102 153 204 255
TAP POSITION
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
2.6
110
100
90
80
70
60
50
40
30
20
10
0
0
SUPPLY CURRENT
vs. SUPPLY VOLTAGE
3.1 3.6 4.1 4.6 5.1
VDD (V)
RESISTANCE (W-TO-L)
vs. TAP POSITION (100kI)
51 102 153 204 255
TAP POSITION
4   _______________________________________________________________________________________