CONFIGURATION REGISTERS
- R/W controls the 3 registers access (read or write):
0 = Write CR1, CR2 ,CR3,
1 = Read CR1, CR2, CR3.
- CF defines the Carrier Frequency as shown onTable 5.
Table 5: Carrier Frequency selection
CF Selected Frequency
0
315MHz
1
434MHz
- MOD sets the data Modulation type:
0 = On/Off Keying (OOK) modulation,
1 = Frequency Shift Keying (FSK) modulation.
- SOE enables the Strobe Oscillator:
0 = Disabled,
1 = Enabled,
Whatever SOE value has been programmed, a high level on STROBE sets the circuit into run mode.
- SR0/SR1 define the Strobe Ratio (SR) as shown on Table 6. SR is the ratio Sleep time over Run time and
Run time=TStrobe (where TStrobe is the Strobe oscillator period).
Table 6: Strobe Ratio selection
SR1 SR0
Strobe Ratio
0
0
3
0
1
7
1
0
15
1
1
31
- DME enables the Data Manager:
0 = Disabled,
1 = Enabled.
Data are output on MOSI and the associated clock on SCLK.
- HE defines if a Header word is present (the bit HE is only active if DME=1):
0 = No header,
1 = Header.
Configuration Register 2 (CR2) defines the Identifier (ID) word content. The bits will be Manchester coded.
Bit name
Reset value
Table 7: Configuration Register 2
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
ID7 ID6 ID5 ID4 ID3 ID2 ID1 ID0
0
0
0
0
0
0
0
0
Table 8 describes the Configuration Register 3 (CR3).
Table 8: Configuration Register 3
Bit name
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
DR1 DR0 MG MS PG
-
-
-
Reset value
1
0
0
0
0
0
0
0
- DR0/DR1 define the Data Rate (before Manchester coding) as shown onTable 9.
MOTOROLA
MC33591 Technical Data
11