Data Sheet, Rev 1.
August 2001
NetLight 1430G5 Type SONET/SDH
Long-Reach Transceivers with Clock Recovery
Application Information (continued)
Table 3. Receiver Optical and Electrical Characteristics (TC = –40 °C to +85 °C; VCC = 3.135 V—3.465 V)
Parameter
Average Sensitivity:*
L-1.1
Maximum Input Power L-1.1*
Link Status Switching Threshold:
Decreasing Light L-1.1
Increasing Light L-1.1
Link Status Hysteresis
Power Supply Current
Output Data Voltage/Clock Voltage:
Low
High
Signal Detect Output Voltage:
Low
High
Clock Duty Cycle
Output Clock Random Jitter
Output Clock Random Jitter Peaking
Clock/Data Alignment L-1.1 (See Figure 2.)
Jitter Tolerance/Jitter Transfer
* For 1 x 10–10 BER with an optical input using 223 – 1 PRBS.
Symbol
Min
Max
Unit
PI
—
PMAX
–10
–34
dBm
—
dBm
LSTD
–45
–35
dBm
LSTI
—
–34.5
dBm
HYS
0.5
6.0
dB
ICCR
—
200
mA
VOL
VCC – 1.86 VCC – 1.50
V
VOH
VCC – 1.025 VCC – 0.88
V
VOL
0.0
0.8
V
VOH
2.4
VCC
V
DC
45
55
%
JC
—
0.01
UI
JP
—
0.1
dB
TCDA
–0.8
0.8
ns
Telcordia Technologies™ GR-253-CORE and
ITU-TG.958 Compliant
DATAOUT
50%
CLOCKOUT
50%
TCDA
Figure 2. Clock/Data Alignment
1-725(F).b
Agere Systems Inc.
5