AD53519
PRELIMINARY TECHNICAL DATA
HOW TO INTERFACE AN ECL OUTPUT TO AN INSTRUMENT WITH A 50 OHM
TO GROUND INPUT
AD53519
+
30
50
VIN
-
30
50
127
127
-5.2 V
ESD PROTECTION CIRCUITS
All input and output pins contain ADI Proprietary ESD
protection diodes.
VCC
EQUIVALENT ESD
PROTECTION CIRCUIT
INPUT
Figure 12
VEE
Figure 11
ESD WARNING!!! ESD (Electrostatic
discharge) sensitive device. Electrostatic
charges as high as 4000 V readily accumulate
on the human body and test equipment and
can discharge without detection. Although
the AD53519 features proprietary ESD
protection circuitry, permanent damage may
occur on devices subjected to high energy
electrostatic discharges. Therefore, proper
ESD precautions are recommended to avoid
performance degradation or loss of
functionality.
TYPICAL PERFORMANCE CHARACTERISTICS (VCC = +5.0V, VEE = -5.20V, TA = +25°C UNLESS OTHERWISE
NOTED)
0
0
0
0
0
0
0
0
0
0
Title
POSSIBLE CHARTS TO BE ADDED.
REV. Pr J July 22, 2002
- 11 -