AD627
Parameter
Conditions
Min
DYNAMIC RESPONSE
Small Signal −3 dB
Bandwidth
G = +5
G = +100
G = +1000
Slew Rate
Settling Time to 0.01% VS = 3 V, 1.5 V output step
G = +5
G = +100
Settling Time to 0.01% VS = 5 V, 2.5 V output step
G = +5
G = +100
Overload Recovery
50% input overload
AD627A
Typ
Max
80
3
0.4
+0.05/−0.07
65
290
85
330
3
AD627B
Min
Typ Max
80
3
0.4
+0.05/−0.07
65
290
85
330
3
1 Does not include effects of External Resistor RG.
2 See Table 8 for total RTI errors.
3 See the Using the AD627 section for more information on the input range, gain range, and common-mode range.
Unit
kHz
kHz
kHz
V/μs
μs
μs
μs
μs
μs
Rev. D | Page 4 of 24