Data Sheet
ADuM1250/ADuM1251
PACKAGE CHARACTERISTICS
Table 3.
Parameter
Resistance (Input to Output)1
Capacitance (Input to Output)1
Input Capacitance
IC Junction to Case Thermal Resistance, Side 1
IC Junction to Case Thermal Resistance, Side 2
Symbol Min Typ Max Unit Test Conditions/Comments
RI-O
1012
Ω
CI-O
1.0
pF f = 1 MHz
CI
4.0
pF
θJCI
46
°C/W Thermocouple located at center of package underside
θJCO
41
°C/W
1 The device is considered a 2-terminal device; Pin 1 through Pin 4 are shorted together, and Pin 5 through Pin 8 are shorted together.
REGULATORY INFORMATION
The ADuM1250/ADuM1251 have been approved by the organizations listed in Table 4.
Table 4.
UL
Recognized Under 1577
Component
Recognition
Program1
Single/Basic 2500 V rms
Isolation Voltage
File E214100
CSA
Approved under CSA Component
Acceptance Notice 5A
Reinforced insulation per
CSA 60950-1-03 and IEC 60950-1,
125 V rms (177 V peak) maximum
working voltage
Basic insulation per CSA 60950-1-03
and IEC 60950-1, 400 V rms (566 V
peak) maximum working voltage
File 205078
CQC
Approved under CQC11-471543-2012
Basic insulation per GB4943.1-2011,
400 V rms (566 V peak) maximum working
voltage, tropical climate, altitude ≤ 5000 m
File CQC14001108691
VDE
Certified according to
DIN V VDE V 0884-10
(VDE V 0884-10): 2006-122
Reinforced insulation,
560 V peak
File 2471900-4880-0001
1 In accordance with UL 1577, each ADuM1250/ADuM1251 is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection
limit = 5 μA).
2 In accordance with DIN V VDE V 0884-10, each ADuM1250/ADuM1251 is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 sec (partial discharge
detection limit = 5 pC). The asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 5.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Maximum Working Voltage Compatible with
50 Year Service Life
Symbol
L(I01)
L(I02)
CTI
VIORM
Value
2500
4.90 min
4.01 min
0.017 min
>400
II
565
Unit
V rms
mm
mm
mm
V
V peak
Test Conditions/Comments
1-minute duration
Measured from input terminals to output
terminals, shortest distance through air
Measured from input terminals to output
terminals, shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Continuous peak voltage across the isolation barrier