AWL6152
APPLICATION INFORMATION
The only external components required for the
AWL6152 are bypass capacitors for the supply and
reference voltages (see Figure 11). When VREF is
pulled down to 0 V, the amplifier is placed in a low-
current shut down mode.
VCC1
22uF tantalum
(optional)
RF IN
VREF
0.01uF
1 VCC
2 RFIN
3 GND
x4 N/C
5 VREF
0.01uF
VCC 10
GND 9
RFOUT 8
GND 7
GND 6
GND
at slug
Figure 11: Application Circuit
RF OUT
10
ADVANCED PRODUCT INFORMATION - Rev 0.2
02/2004