PRELIMINARY
CY7C63000/CY7C63001
CY7C63100/CY7C63101
CY7C63200/CY7C63201
7.0
tsink
Tratio
Imax
Pmax
Vith
VH
VOL1
VOL2
DC Characteristics (continued) Fosc = 6 MHz; Operating Temperature = 0 to 70°C
Parameter
Current sink response time
General Purpose I/O (continued)
Tracking Ratio Port1 to Port0
Port 1 max sink current
Port 1 & CEXT sink mode dissipation
Input Threshold Voltage
Input Hysteresis Voltage
Output LOW Voltage, Cext pin
Output LOW Voltage, Cext pin
Min Max Units
Conditions
0.8
µs Full scale transition
13.6
45%
6%
18.4
60
25
65%
12%
0.4
2.0
Vout = 2.0V[9]
mA Summed over all Port 1 bits
mW Per pin
Vcc All ports and Cext [7]
Vcc All ports and Cext [8]
V VCC = Min., IOL = 2mA
V VCC = Min., IOL = 5mA
8.0 Switching Characteristics
Parameter
tCYC
tCH
tCL
tr
tf
Description
Input clock cycle time
Clock HIGH time
Clock LOW time
Transition Rise Time [1, 4, 8]
Transition Fall Time [1, 4, 8]
Min.
166.67
0.45 tCYC
0.45 tCYC
75
75
Max.
166.67
300
300
Unit
ns
ns
ns
ns
ns
Notes:
4. 4.35 V to 5.25 V VCC.
5. Measured as largest step size vs nominal according to measured full scale and zero programmed values.
6. POR can occur only once per applied VCC, if VCC drops below Vrst, POR will not re-occur. VCC must return to 0.0V before POR will be re-applied on a subsequent
VCC ramp.
7. Low to High transition
8. This parameter is guaranteed, but not tested.
9. Tratio = Isink1(n)/Isink0(n) for the same n
10. Irange = Isink(F)/Isink(O) for port 0 or 1 output
23