EMBEDDED ALGORITHMS
Flowchart 1. Embedded Program
START
Write Program
Command Sequence
(shown below)
Data Poll Device
Verify Data?
Increment
Address
No
Last
Address?
Yes
Programming Done
Flowchart 2. Embedded Program Command Sequence
See the Command Definitions section for more information on WORD mode.
EN29LV800
555H / AAH
2AAH / 55H
555H / A0H
PROGRAM ADDRESS / PROGRAM DATA