Surge arrester
3-electrode arrester
B88069X5171B502
EZ3-A230X
Features
Extremely small size
Fast response time
High current rating
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
Applications
Branch exchange (MDF)
Line protection
Station protection
Electrical specifications
DC spark-over voltage 1) 2) 4)
Impulse spark-over voltage 4)
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
Service life
10 operations
1 operation
10 operations [5x (+) & 5x (–)]
1 operation
300 operations (alternating polarity)
Insulation resistance at 100 Vdc 4)
50 Hz, 1 s 5)
50 Hz, 0.18 s 5)
8/20 µs 5)
10/350 µs 5)
10/1000 µs 5)
Capacitance at 1 MHz 4)
DC holdover voltage 3)
at 135 Vdc / 1300 Ω
Transverse delay time 3)
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, blue, negative
230
V
± 20
%
< 600
V
< 450
V
< 750
V
< 600
V
5
A
5
A
5
kA
1
kA
200
A
>1
GΩ
< 1.5
pF
< 150
ms
< 0.2
µs
~ 10
V
~1
A
~ 80
V
~ 0.8
g
-40 ... +90
°C
40/ 90/ 21
EZ 230 YY O
EZ
- Series
230 - Nominal voltage
YY
- Year of production
O
- Non radioactive
KB AB E / KB AB PM
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 4