Preliminary Data Sheet
September 2001
L9216A/G
Short-Loop Ringing SLIC with Ground Start
Electrical Characteristics
Table 6. Environmental Characteristics
Temperature Range
Humidity Range1
Parameter
1. Not to exceed 26 grams of water per kilogram of dry air.
Table 7. 5 V Supply Currents
VBAT1 = –70 V, VBAT2 = –21 V, VCC = 5 V.
Parameter
Supply Currents (scan state; no loop current):
IVCC
IVBAT1
IVBAT2
Supply Currents (forward/reverse active; no loop current, with or without PPM,
VBAT2 applied):
IVCC
IVBAT1
IVBAT2
Supply Currents (on-hook transmission mode; no loop current, with or without
PPM, VBAT1 applied):
IVCC
IVBAT1
IVBAT2
Supply Currents (disconnect mode):
IVCC
IVBAT1
IVBAT2
Supply Currents (ground start mode, no loop current):
IVCC
IVBAT1
IVBAT2
Supply Currents (ring mode; no load):
IVCC
IVBAT1
IVBAT2
Min Typ Max Unit
–40 — 85 °C
5
— 951 %RH
Min Typ Max Unit
— 4.30 4.80 mA
— 0.24 0.35 mA
—
3
6
µA
— 5.95 7.0 mA
—
25
85
µA
— 1.2 1.40 mA
— 6.0 7.0 mA
— 1.5 1.9 mA
— 1.5
6
µA
— 2.7 3.75 mA
—
15 110 µA
— 3.5 25 µA
— 4.0 — mA
— 0.24 — mA
—
2
— µA
— 5.9 6.5 mA
— 1.8 2.2 mA
—
2
6
µA
Table 8. 5 V Powering
VBAT1 = –70 V, VBAT2 = –21 V, VCC = 5 V.
Parameter
Min Typ Max Unit
Power Dissipation (scan state; no loop current)
— 38 46 mW
Power Dissipation (forward/reverse active; no loop current, VBAT2 applied)
— 57 64 mW
Power Dissipation (on-hook transmission mode; no loop current, VBAT1 applied) — 135 165 mW
Power Dissipation (disconnect mode)
— 14 23 mW
Power Dissipation (ground start mode)
— 37 — mW
Power Dissipation (ring mode; no load)
— 156 184 mW
Agere Systems Inc.
13