Electrical Characteristics TA=25°C
Mimimum and maximum values are testing require-
ments. Typical values are characteristics of the device
and are the result of engineering evaluations. Typical
values are for information purposes only and are not
part of the testing requirements.
Parameter
Input
LED Forward Current for Switch Turn-on
LED Forward Current for Switch Turn-off
LED Forward Voltage
Output
ON-resistance:
ac/dc, each pole
dc Pins 4, 6 (+) to 5 (–) (LH1525 only)
OFF-resistance
Current Limit
Output Off-state Leakage Current
Output Capacitance
Switch Offset
Transfer
Input/Output Capacitance
Turn-on Time
Turn-off Time
Symbol Test Condition
Min
Typ Max
Unit
IFon IL=100 mA, t=10 ms
IFoff VL= ±350 V, t=100 ms
VF IF=1.5 mA
—
0.3
0.5
mA
0.001
0.1
—
mA
0.80
1.15 1.40
V
RON
ROFF
ILMT
—
—
—
IF=1.5 mA, IL=±50 mA
IF=1.5 mA, IL=100 mA
IF=0 mA, VL=±100 V
IF=1.5 mA, t=5 ms, VL=7 V
IF=0 mA, VL=±100 V
IF=0 mA, VL=±400 V
IF=0 mA, VL=1 V
IF=0 mA, VL=50 V
IF=5 mA
17
25
33
W
4.25
6.25 8.25
W
—
5000
—
GW
170
210 270
mA
—
0.04 200
nA
—
—
1.0
mA
—
37
—
pF
—
13
—
pF
—
0.25
—
mV
CISO
ton
toff
VISO=1 V
IF=1.5 mA, IL=50 mA
IF=5.0 mA, IL=50 mA
IF=1.5 mA, IL=50 mA
IF=5.0 mA, IL=50 mA
—
0.8
—
pF
—
1.00
—
ms
—
0.25 0.8
ms
—
0.20
—
ms
—
0.25 0.4
ms
Siemens Microelectronics, Inc. • Optoelectronics Division
www.smi.siemens.com/opto/
15 of 25
LH1525AT/AAB, LH1526AB/AAC
October 1998