M5295AL/AP/AFP
Application Example
M5295A
12345678
Clock
RST1
(RESET)
MCU/MPU
RST2
(HOLD)
VDD
Figure 8 Application Example
Notice for Use
1. When malfunction occurs due to noise or order related trouble, connect capacitance of approximately 1000 pF
between pin (5) and GND as well as pin (8) and GND to stabilize operation.
2. To adjust detection voltage, add resistance of 15 kΩ or less to both VCC and GND via adjusting pins. (Set detection
voltage to no less than 3 V.)
3. Set tWD and tRST(2) as shown below:
110 µs ≤ tWD ≤ 1.1 s
8.3 µs ≤ tRST(2) ≤ 83 ms
10 kΩ ≤ R1 ≤ 30 kΩ
4. Input clock pulses to pin (1) via capacitor. To determine capacitance, refer to “Relationship between input pulse
width and input capacitance Cin”.
Backup power supply
M5295A
10kΩ 3.5V
R4
12345678
R3
VCC
RESET output
To System
Backup switching voltage VTH2(L) Switching voltage calculation formula
VTH2(L) =
R03 + R04
R04
× 1.24 (V)
R03 = R3 // 51.2kΩ
R04 = R4 // 18.8kΩ
Note: Set backup switching voltage to be more than or equal to backup supply voltage.
Figure 9 Example of Backup Circuit with M5295AL
REJ03D0780-0200 Rev.2.00 Jun 15, 2007
Page 8 of 12