MB88153
■ ELECTRICAL CHARACTERISTICS
• DC Characteristics
(Ta = − 40 °C to + 85 °C, VDD = 3.3 V ± 0.3 V, VSS = 0.0 V)
Parameter
Symbol Pin
Conditions
Value
Unit
Min
Typ
Max
Output voltage
VOH
CKOUT
“H” level output
IOH = − 4 mA
VOL
CKOUT
“L” level output
IOL = 4 mA
VDD − 0.5
⎯
VSS
⎯
VDD
V
0.4
V
Output impedance
ZO CKOUT 16.6 MHz to 134 MHz
⎯
45
⎯
Ω
Input capacitance
CKIN,
ENS, Ta = + 25 °C,
CIN FREQ0, VDD = VI = 0.0 V,
FREQ1, f = 1 MHz
XPD
⎯
⎯
16
pF
16.6 MHz to 67 MHz
⎯
⎯
15
Load capacitance
CL CKOUT 67 MHz to 100 MHz
⎯
⎯
10
pF
100 MHz to 134 MHz
⎯
⎯
7
Input Pull-up resistance
RPU
FREQ0,
XPD
VIL = 0.0 V
25
50
200 kΩ
Power supply current
ICC
VDD
No load capacitance
at 24 MHz output
⎯
4.0
6.0 mA
Power down current
Ipd
VDD Input clock stopping
⎯
⎯
600 µA
• AC Characteristics
Parameter
Input frequency
Output frequency
Output slew rate
Output clock duty cycle
Modulation frequency
Lock-up time
Cycle-cycle jitter
(Ta = − 40 °C to + 85 °C, VDD = 3.3 V ± 0.3 V, VSS = 0.0 V)
Symbol Pin
Conditions
Value
Unit
Min
Typ
Max
fin
CKIN
⎯
16.6
⎯
134 MHz
fOUT CKOUT
⎯
16.6
⎯
134 MHz
SR
CKOUT
Load capacitance 15 pF
0.4 V to 2.4 V
0.4
⎯
4.0 V/ns
tDCC CKOUT 1.5 V
40
⎯
60
%
fMOD CKOUT
⎯
⎯
12.5
⎯
kHz
tLK CKOUT
⎯
⎯
2
5
ms
No load capacitance,
tJC
CKOUT
Ta = + 25 °C,
VDD = 3.3 V,
⎯
⎯
100
ps
Standard deviation σ
Note : The modulation clock stabilization wait time is required after the power is turned on, the IC recovers from
power saving, or after FREQ (frequency range) or ENS (modulation ON/OFF) setting is changed. For the
modulation clock stabilization wait time, assign the maximum value for lock-up time.
10