DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MC-458CB64ESB Просмотр технического описания (PDF) - NEC => Renesas Technology

Номер в каталоге
Компоненты Описание
производитель
MC-458CB64ESB
NEC
NEC => Renesas Technology 
MC-458CB64ESB Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MC-458CB64ESB, 458CB64PSB
DC Characteristics (Recommended Operating Conditions unless otherwise noted)
Parameter
Symbol
Test condition
MIN. MAX. Unit Notes
Operating current
ICC1 Burst length = 1, tRC tRC(MIN.)
IO = 0 mA
/CAS latency = 2
/CAS latency = 3
440 mA 1
440
Precharge standby current ICC2P CKE VIL(MAX.), tCK = 15 ns
5 in power down mode
ICC2PS CKE VIL(MAX.), tCK =
Precharge standby current ICC2N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
in non power down mode
Input signals are changed one time during 30 ns.
4 mA
4
80 mA
Active standby current in
ICC2NS CKE VIH(MIN.), tCK = , Input signals are stable.
ICC3P CKE VIL(MAX.), tCK = 15 ns
32
20 mA
power down mode
Active standby current in
non power down mode
ICC3PS CKE VIL(MAX.), tCK =
ICC3N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
Input signals are changed one time during 30 ns.
16
120 mA
Operating current
ICC3NS CKE VIH(MIN.), tCK = , Input signals are stable.
ICC4 tCK tCK(MIN.) , IO = 0 mA
/CAS latency = 2
80
400 mA 2
(Burst mode)
/CAS latency = 3
560
CBR (Auto) refresh current ICC5 tRC tRC(MIN.)
/CAS latency = 2
880 mA 3
/CAS latency = 3
880
Self refresh current
ICC6 CKE 0.2 V
8 mA
Input leakage current
Output leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
IO(L) DOUT is disabled, VO = 0 to 3.6 V
– 4 + 4 µA
– 1.5 + 1.5 µA
High level output voltage
VOH IO = – 4.0 mA
2.4
V
Low level output voltage
VOL IO = + 4.0 mA
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK(MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK(MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK(MIN.).
6
Data Sheet M12263EJAV0DS00

Share Link: 