AC Electrical Characteristics
Symbol
Parameter
TA = −40°C to +85°C, CL = 50 pF
VCC
(V)
Min
Typ
Max
Units
(Note 6)
tPLH,
Data Propagation Delay
tPHL
An to Cn, Dn or Bn to Dn, Cn (Note 7)
tPLH,
Switch Exchange Time
tPHL
BX to An, Bn, Cn, Dn
tPZL,
Switch Enable Time
tPZH
BE to An, Bn, Cn or Dn
tPLZ,
Switch Disable Time
tPHZ
BE to An, Bn, Cn, or Dn
Note 6: All typical values are at VCC = 5.0V, TA = 25°C.
4.75
4.75
1.5
4.75
1.5
4.75
1.5
0.25
ns
6.5
ns
6.5
ns
5.5
ns
Note 7: This parameter is guaranteed by design but not tested. The bus switch contributes no propagation delay other than the RC delay of the On resis-
tance of the switch and the load capacitance. The time constant for the switch and alone is of the order of 0.25 ns for 50 pF load. Since this time constant is
much smaller than the rise/fall times of typical driving signals, it adds very little propagation delay to the system. Propagation delay of the bus switch when
used in a system is determined by the driving circuit on the driving side of the switch and its interaction with the load on the driven side.
Capacitance (Note 8)
Symbol
Parameter
CIN
Control Input Capacitance
CI/O (OFF)
Input/Output Capacitance
Note 8: Capacitance is characterized but not tested.
Typ
Max
Units
4
6
pF
9
13
pF
Conditions
VCC = 5.0V
VCC = 5.0V
On-Resistance (RON) vs Input Voltage
(VCC = 5.0V)
3