NJM2886
■ TYPICAL APPLICATION
x In the case where ON/OFF Control is not required:
VIN
VIN
VO
0.33uF
NJM2886
R
(0~300kΩ)
CONTROL
GND
VO
2.2uF
OR
4.7uF(Vo≤2.6V)
Connect control terminal to VIN terminal
The quiescent current can be reduced by using a resistance “R”. Instead, it increases the minimum operating voltage.
For further information, please refer to Figure “Output Voltage vs. Control Voltage”.
y In use of ON/OFF CONTROL:
VIN
0.33uF
R
VIN
VO
NJM2886
CONTROL
GND
VO
2.2uF
OR
4.7uF(Vo≤2.6V)
State of control terminal:
•“H”→ output is enabled.
• “L” or “open” → output is disabled.
-4-
Ver.2003-08-22