P4C1256L
RECOMMENDED OPERATING TEMPERATURE & SUPPLY VOLTAGE
Temperature Range (Ambient)
Commercial (0°C to 70°C)
Industrial (-40°C to 85°C)
Supply Voltage
4.5V ≤ VCC ≤ 5.5V
4.5 ≤ VCC ≤ 5.5V
MAXIMUM RATINGS(1)
Stresses greater than those listed can cause permanent damage to the device. These are absolute stress ratings
only. Functional operation of the device is not implied at these or any other conditions in excess of those given in
the operational sections of this data sheet. Exposure to Maximum Ratings for extended periods can adversely
affect device reliability.
Symbol
VCC
V
TERM
T
A
S
TG
IOUT
ILAT
Parameter
Supply Voltage with Respect to GND
Terminal Voltage with Respect to GND (up to 7.0V)
Operating Ambient Temperature
Storage Temperature
Output Current into Low Outputs
Latch-up Current
Min
-0.5
-0.5
-55
-65
>200
Max
7.0
VCC + 0.5
125
150
25
Unit
V
V
°C
°C
mA
mA
DC ELECTRICAL CHARACTERISTICS
(Over Recommended Operating Temperature & Supply Voltage)(2)
Symbol
V
OH
VOL
VIH
VIL
I
LI
ILO
ISB
Parameter
Output High Voltage
(I/O0 - I/O7)
Output Low Voltage
(I/O0 - I/O7)
Input High Voltage
Input Low Voltage
Input Leakage Current
Output Leakage Current
V Current
CC
TTL Standby Current
(TTL Input Levels)
Test Conditions
IOH = –1mA, VCC = 4.5V
IOL = 2.1mA
GND ≤ VIN ≤ VCC
GND ≤ VOUT ≤ VCC
CE
≥
V
IH
Ind'l.
Com'l.
Ind'l.
Com'l.
VCC = 5.5V, IOUT = 0 mA
CE = VIH
ISB1
V Current
CC
CMOS Standby Current
(CMOS Input Levels)
VCC = 5.5V, IOUT = 0 mA
CE ≥ VCC -0.2V
Min
2.4
2.2
-0.5(3)
-5
-2
-5
-2
Max
0.4
VCC + 0.3
0.8
+5
+2
+5
+2
3
100
Unit
V
V
V
V
µA
µA
mA
µA
Document # SRAM121 REV E