PI74ALVCH16344
123456789012345678901234567890121234567890123456789012345678901212345678910-1B23i4t56t7o89401-2B34i5t6A789d0d12r1e23s4s56D78r90iv12e3r45w678i9t0h12334-5S67t8a90t1e21O23u45t6p78u9t01s2
DC Electrical Characteristics (Over the Operating Range, TA = 40°C to +85°C, VCC = 3.3V ±10%)
Parameters
Test Conditions
VCC
Min. Typ.(1) Max. Units
IOH = 100µA
1.65V to 3.6V VCC 0.2
IOH = 4mA
1.65V
1.2
IOH = 6mA
2.3V
2.0
VOH
IOH = 12mA
2.3V
1.7
2.7V
2.2
3.0V
2.4
IOH = 24mA
3.0V
2.0
V
IOL = 100µA
1.65V to 3.6V
0.2
IOL = 4mA
1.65V
0.45
IOL = 6mA
2.3V
0.4
VOL
2.3V
0.7
IOL = 12mA
2.7V
0.4
IOL = 24mA
3V
0.55
II
VI = VCC or GND
3.6V
±5
VI = 0.58V
VI = 1.07V
25
1.65V
25
II (Hold)
VI = 0.7V
VI = 1.7V
45
2.3V
45
IOZ(3)
VI = 0.8V
VI = 2V
VI = 0 to 3.6V(2)
VO = VCC or GND
75
3V
75
3.6V
3.6V
µA
±500
±10
ICC
VI = VCC or GND IO = 0
3.6V
20
∆ICC
One input at VCC 0.6V,
Other inputs at VCC or GND
3V to 3.6V
750
CI Control Inputs VI = VCC or GND
CIO A or B ports VO = VCC or GND
3.3V
3.3V
4
pF
8
Notes:
1. All typical values are at VCC = 3.3V, TA = 25ºC.
2. This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to
switch the input from one state to another.
3. For I/O ports, the IOZ includes the input leakage current.
4
PS8166B 10/19/99