DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

SC18IS602B Просмотр технического описания (PDF) - NXP Semiconductors.

Номер в каталоге
Компоненты Описание
производитель
SC18IS602B
NXP
NXP Semiconductors. 
SC18IS602B Datasheet PDF : 25 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
NXP Semiconductors
SC18IS602/602B/603
I2C-bus to SPI bridge
7.1.1 Addressing
R/W
slave address
Fig 5. Slave address
0 1 0 1 A2 A1 A0 X
fixed
programmable
002aac446
The first seven bits of the first byte sent after a START condition defines the slave address
of the device being accessed on the bus. The eighth bit determines the direction of the
message. A ‘0’ in the least significant position of the first byte means that the master will
write information to a selected slave. A ‘1’ in this position means that the master will read
information from the slave. When an address is sent, each device in a system compares
the first seven bits after the START condition with its address. If they match, the device
considers itself addressed by the master as a slave-receiver or slave-transmitter,
depending on the R/W bit.
A slave address of the SC18IS602/602B/603 is comprised of a fixed and a programmable
part. The programmable part of the slave address enables the maximum possible number
of such devices to be connected to the I2C-bus. Since the SC18IS602/602B/603 have
three programmable address bits (defined by the A2, A1, and A0 pins), it is possible to
have eight of these devices on the same bus.
The state of the A2, A1, and A0 pins are latched at reset. Changes made after reset will
not alter the address.
7.1.2 Write to data buffer
All communications to or from the SC18IS602/602B/603 occur through the data buffer.
The data buffer is 200 bytes deep. A message begins with the SC18IS60x address,
followed by the Function ID. Depending upon the Function ID, zero to 200 data bytes can
follow.
The SC18IS60x will place the data received into a buffer and continue loading the buffer
until a STOP condition is received. After the STOP condition is detected, further
communications will not be acknowledged until the function designated by the Function ID
has been completed.
S SLAVE ADDRESS W A
Fig 6. Write to data buffer
FUNCTION ID
A 0 TO 200 BYTES A P
002aac447
7.1.3 SPI read and write - Function ID 01h to 0Fh
Data in the buffer will be sent to the SPI port if the Function ID is 01h to 0Fh. The Function
ID contains the Slave Select (SS) to be used for the transmission on the SPI port. There
are four Slave Selects that can be used, with each SS being selected by one of the bits in
SC18IS602_602B_603_4
Product data sheet
Rev. 04 — 11 March 2008
© NXP B.V. 2008. All rights reserved.
5 of 25

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]