Calling Line Identifier plus Call Waiting (Type II)
17
6. Performance Specification
6.1 Electrical Performance
6.1.1 Absolute Maximum Ratings
Exceeding these maximum ratings can result in damage to the device.
CMX602B PRELIMINARY INFORMATION
Supply (VDD - VSS)
Voltage on any pin to VSS
Current into or out of VDD and VSS pins
Current into or out of any other pin
D4 / P3 Package
Total Allowable Power Dissipation at TAMB = 25°C
Derating above 25°C°
Storage Temperature
Operating Temperature
E4 Package
Total Allowable Power Dissipation at TAMB = 25°C
Derating above 25°C°
Storage Temperature
Operating Temperature
Min.
-0.3
-0.3
-30
-20
-55
-40
-55
-40
6.1.2 Operating Limits
Correct operation of the device outside these limits is not implied.
Max.
7.0
VDD + 0.3
30
20
Units
V
V
mA
mA
800
mW
13
mW/°C above 25°C
125
°C
85
°C
300
mW
5
mW/°C above 25°C
125
°C
85
°C
Supply (VDD - VSS)
Operating Temperature
Xtal frequency
Notes
1
1
2
Min.
2.7
-40
3.575965
Max.
5.5
85
3.583125
Units
V
°C
MHz
Operating Limits Notes:
1. Operating temperature range –10°C to 60°C at VDD < 3.0V.
2. A Xtal frequency of 3.579545MHz ±0.1% is required for correct Tone Alert and FSK detection.
2000 MX-COM, Inc
www.mxcom.com Tel: 800 638 5577 336 744 5050 Fax: 336 744 5054
Doc. # 20480204.002