NXP Semiconductors
TJA1083
FlexRay node transceiver
6.1.1.1 Bus activity and idle detection
In Normal mode, bus activity and bus idle are detected as follows:
Bus activity is detected when the absolute differential voltage on the bus lines is
higher than Vi(dif)det(act)for tdet(act)(bus):
If the differential voltage on the bus lines is lower than VIL(dif) after bus activity has
been detected, pin RXD switches LOW.
If the differential voltage on the bus lines is higher than VIH(dif) after bus activity has
been detected, pin RXD remains HIGH.
Bus idle is detected when the absolute differential voltage on the bus lines is lower
than Vi(dif)det(act)for tdet(idle)(bus). This results in pin RXD being switched HIGH or
staying HIGH.
6.1.2 Standby mode
Standby mode is a low-power mode featuring very low current consumption. In Standby
mode, the transceiver is unable to transmit or receive data since both the transmitter and
the normal receiver are switched off. The low-power receiver is activated to monitor the
bus for wake-up activity, provided an undervoltage has not been detected on pin VCC.
The low-power receiver is deactivated if an undervoltage is detected on pin VCC - with the
result that the wake flag is not set if a wake-up pattern or dedicated data frame is
received.
Pins ERRN and RXD indicate the status of the wake flag when VIO and VCC are within
their operating ranges. See Table 3 for a description of pins ERRN and RXD when an
undervoltage is detected on pin VIO or pin VCC.
The status register cannot be read via the SPI interface if an undervoltage is detected on
pin VIO.
The BGE input has no effect in Standby mode.
6.1.3 Power-off mode
The transmitter and the two receivers (normal and low-power) are deactivated in
Power-off mode. As a result, the wake flag is not set if a wake-up pattern or dedicated
data frame is received. If the voltage at VCC rises above Vth(rec)POR, the transceiver
switches to Standby mode and the digital section is reset. If VCC subsequently drops
below Vth(det)POR, the transceiver reverts to Power-off mode (see Section 6.2).
The status register cannot be read via the SPI interface in Power-off mode.
6.1.4 State transitions
Figure 4 shows the TJA1083 state transition diagram. The timing diagram for the ERRN
indication signal during transitions between Normal and Standby modes, when the error
flag is set and the wake flag is not set, is illustrated in Figure 5 and described in Table 6.