MC74LCX00
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Min
Type
Max
VCC
Supply Voltage
Operating
Data Retention Only
2.0
2.5, 3.3
3.6
1.5
2.5, 3.3
3.6
VI
Input Voltage
VO
Output Voltage
0
5.5
(HIGH or LOW State)
0
VCC
(3−State)
IOH
HIGH Level Output Current
VCC = 3.0 V − 3.6 V
−24
VCC = 2.7 V − 3.0 V
−12
VCC = 2.3 V − 2.7 V
−8
IOL
LOW Level Output Current
VCC = 3.0 V − 3.6 V
+24
VCC = 2.7 V − 3.0 V
+12
VCC = 2.3 V − 2.7 V
+8
TA
Operating Free−Air Temperature
−40
+85
Dt/DV
Input Transition Rise or Fall Rate, VIN from 0.8 V to 2.0 V, VCC = 3.0 V
0
10
Unit
V
V
V
mA
mA
C
ns/V
DC ELECTRICAL CHARACTERISTICS
Symbol
Characteristic
Condition
VIH
HIGH Level Input Voltage (Note 2)
VIL
LOW Level Input Voltage (Note 2)
VOH
HIGH Level Output Voltage
2.3 V VCC 2.7 V
2.7 V VCC 3.6 V
2.3 V VCC 2.7 V
2.7 V VCC 3.6 V
2.3 V VCC 3.6 V; IOH = −100 mA
VCC = 2.3 V; IOH = −8 mA
VCC = 2.7 V; IOH = −12 mA
VCC = 3.0 V; IOH = −18 mA
VOL
LOW Level Output Voltage
VCC = 3.0 V; IOH = −24 mA
2.3 V VCC 3.6 V; IOL = 100 mA
VCC = 2.3 V; IOL = 8 mA
VCC = 2.7 V; IOL = 12 mA
VCC = 3.0 V; IOL = 16 mA
VCC = 3.0 V; IOL = 24 mA
IOFF
Power Off Leakage Current
VCC = 0, VIN = 5.5 V or VOUT = 5.5 V
IIN
Input Leakage Current
VCC = 3.6 V, VIN = 5.5 V or GND
ICC
Quiescent Supply Current
VCC = 3.6 V, VIN = 5.5 V or GND
DICC
Increase in ICC per Input
2.3 VCC 3.6 V; VIH = VCC − 0.6 V
2. These values of VI are used to test DC electrical characteristics only.
TA = −40C to +85C
Min
Max
Unit
1.7
V
2.0
0.7
V
0.8
VCC − 0.2
V
1.8
2.2
2.4
2.2
0.2
V
0.6
0.4
0.4
0.55
10
mA
5
mA
10
mA
500
mA
http://onsemi.com