Nexperia
74LVT16373A
3.3 V 16-bit transparent D-type latch; 3-state
8. Recommended operating conditions
Table 5. Recommended operating conditions
Symbol Parameter
Conditions
VCC
supply voltage
VI
input voltage
Δt/ΔV input transition rise and fall rate outputs enabled
Tamb
ambient temperature
in free-air
Min
Typ
Max Unit
2.7
-
3.6 V
0
-
5.5 V
-
-
10 ns/V
-40
+25
+85 °C
9. Static characteristics
Table 6. Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
VIK
input clamping voltage VCC = 2.7 V; IIK = -18 mA
VIH
HIGH-level input voltage
VIL
LOW-level input voltage
VOH
HIGH-level output
voltage
VCC = 2.7 V to 3.6 V; IOH = -100 μA
VCC = 2.7 V; IOH = -8 mA
VCC = 3.0 V; IOH = -32 mA
VOL
LOW-level output
voltage
VCC = 2.7 V; IOL = 100 μA
VCC = 2.7 V; IOL = 24 mA
VCC = 3.0 V; IOL = 16 mA
VCC = 3.0 V; IOL = 32 mA
VCC = 3.0 V; IOL = 64 mA
IOH
HIGH-level output
current
-
2.0
-
VCC - 0.2
2.4
2.0
-
-
-
-
-
-
IOL
LOW-level output current
-
current duty cycle ≤ 50%; f ≥ 1kHz
-
VOL(pu) power-up LOW-level
VCC = 3.6 V; IO = 1 mA; VI = VCC or GND [2]
-
output voltage
II
input leakage current all input pins
VCC = 0 V or 3.6 V; VI = 5.5 V
-
control pins
VCC = 3.6 V; VI = VCC or GND
data pins
-
[3]
VCC = 3.6 V; VI = VCC
-
VCC = 3.6 V; VI = 0 V
-
IOFF
power-off leakage
VCC = 0 V; VI or VO = 0 V to 4.5 V
-
current
IBHL
IBHH
IBHLO
bus hold LOW current
bus hold HIGH current
bus hold LOW overdrive
current
nDn input; VCC = 3 V; VI = 0.8 V
nDn input; VCC = 3 V; VI = 2.0 V
nDn input; VCC = 3.6 V; VI = 0 V to 3.6 V
75
-75
[4] 500
IBHHO bus hold HIGH overdrive nDn input; VCC = 3.6 V; VI = 0 V to 3.6 V
[4]
-
current
Typ[1]
-0.85
-
-
VCC
2.5
2.3
0.07
0.3
0.25
0.3
0.4
-
-
-
0.1
0.4
±0.1
0.1
-0.4
0.1
135
-135
-
-
Max Unit
-1.2 V
-V
0.8 V
-V
-V
-V
0.2 V
0.5 V
0.4 V
0.5 V
0.55 V
-32 mA
32 mA
64 mA
0.55 V
10 μA
±1 μA
1 μA
-5 μA
±100 μA
- μA
- μA
- μA
-500 μA
74LVT16373A
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 3 — 1 October 2018
© Nexperia B.V. 2018. All rights reserved
5 / 14