Absolute Maximum Ratings (Note 4) (@TA = +25°C, unless otherwise specified.)
Symbol
Description
Rating
ESD HBM
Human Body Model ESD Protection
2
ESD CDM
Charged Device Model ESD Protection
1
ESD MM
Machine Model ESD Protection
200
VCC
VI
Vo
IIK
IOK
IOK
IO
ICC
IGND
TJ
TSTG
PTOT
Supply Voltage Range
Input Voltage Range
Voltage applied to output in high or low state
Input Clamp Current VI < -0.5V
Output Clamp Current VO < -0.5V
Output Clamp Current VO > VCC +0.5 V
Continuous output current
Continuous current through VCC
Continuous current through GND
Operating Junction Temperature
Storage Temperature
Total Power Dissipation
-0.5 to 7.0
-0.5 to 7.0
-0.3 to VCC +0.5
-20
-20
20
+/- 25
75
-75
-40 to +150
-65 to +150
500
Notes: 4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device
operation should be within recommend values.
Unit
KV
KV
V
V
V
V
mA
mA
mA
mA
mA
mA
°C
°C
mW
Recommended Operating Conditions (Note 5) (@TA = +25°C, unless otherwise specified.)
Symbol
Parameter
VCC
Supply Voltage
Conditions
VI
Input Voltage
VO
t/V
Output Voltage
Input transition rise or fall rate
Active Mode
VCC = 3.0 V ± 0.3 V
VCC = 5.0 V ± 0.5 V
TA
Operating free-air temperature
Notes: 5. Unused inputs should be held at VCC or Ground.
Min
Max
Unit
2.0
5.5
V
0
5.5
V
0
VCC
V
100
ns/V
20
-40
+125
°C
74AHC138
Document number: DS35482 Rev. 2 - 2
4 of 10
www.diodes.com
June 2013