BA6219BFP-Y, BA6222
Interfaces
IN1
20k
IN2
10k
10k
10k
Fig. 20 IN1, IN2 (BA6219BFP-Y, BA6222)
CD1
Technical Note
VR
Fig.21 VR (BA6222)
VCC2
VCC1
CD2
VR
OUT1 OUT2
GND
Fig. 22 VCC1, VCC2, VR, CD1, CD2, GND (BA6219BFP-Y)
CD1
VCC2
VCC1
CD2
OUT1 OUT2
GND
Fig. 23 VCC1, VCC2, CD1, CD2, GND (BA6222)
Notes for use
1) Absolute maximum ratings
Devices may be destroyed when supply voltage or operating temperature exceeds the absolute maximum rating.
Because the cause of this damage cannot be identified as, for example, a short circuit or an open circuit, it is important
to consider circuit protection measures – such as adding fuses – if any value in excess of absolute maximum ratings is
to be implemented.
2) Connecting the power supply connector backward
Connecting the power supply in reverse polarity can damage the IC. Take precautions against reverse polarity when
connecting the power supply lines, such as adding an external direction diode.
www.rohm.com
○c 2009 ROHM Co., Ltd. All rights reserved.
7/10