Recommended Operating Conditions
The Recommended Operating Conditions table defines the conditions for actual device operation. Recommended
operating conditions are specified to ensure optimal performance to the datasheet specifications. Fairchild does not
recommend exceeding them or designing to absolute maximum ratings.
Symbol
Parameter
Min.
Max.
Unit
TA
IF(ON)
VF(OFF)
VCC
VDD – VSS
VDD – VE
VE – VSS
tPW
Ambient Operating Temperature
Input Current (ON)
Input Voltage (OFF)
Supply Voltage
Total Output Supply Voltage
Positive Output Supply Voltage(7)
Negative Output Supply Voltage
Input Pulse Width
-40
+100
ºC
7
16
mA
-3.6
0.8
V
3
15
V
15
30
V
15
30 – (VE – VSS)
V
0
15
V
500
ns
Note:
7. During power up or down, ensure that both the input and output supply voltages reach the proper recommended
operating voltages to avoid any momentary instability at the output state.
Isolation Characteristics
Apply over all recommended conditions; typical value is measured at TA = 25ºC.
Symbol
Parameter
Conditions
Min. Typ. Max. Units
VISO
Input-Output Isolation TA = 25°C, Relative Humidity < 50%,
Voltage
t = 1.0 minute, II-O ≤ 10 µA, 50 Hz
(8)(9)(10)
4,243
VRMS
RISO
Isolation Resistance VI-O = 500 V(8)
1011
CISO
Isolation Capacitance VI-O = 0 V, Frequency = 1.0 MHz(8)
1
pF
Notes:
8. Device is considered a two-terminal device: pins 1 to 8 are shorted together and pins 9 to 16 are shorted together.
9. 4,243 VRMS for 1-minute duration is equivalent to 5,091 VRMS for 1-second duration.
10. The input-output isolation voltage is a dielectric voltage rating per UL1577. It should not be regarded as an
input-output continuous voltage rating. For the continuous working voltage rating, refer to equipment-level safety
specification or DIN EN/IEC 60747-5-5 Safety and Insulation Ratings Table on page 4.
©2014 Fairchild Semiconductor Corporation
FOD8333 Rev. 1.0.3
6
www.fairchildsemi.com