DATA SHEET
AC CHARACTERISTICS
555 for program
2AA for erase
PA for program
SA for sector erase
555 for chip erase
Data# Polling
Addresses
WE#
OE#
PA
tWC
tAS
tAH
tWH
tGHEL
tCP
tWHWH1 or 2
CE#
Data
tWS
tCPH
tDS
tDH
A0 for program
55 for erase
PD for program
30 for sector erase
10 for chip erase
DQ7# DOUT
Notes:
1. PA = Program Address, PD = Program Data, DQ7# = complement of data written to device, DOUT = data written to device.
2. Figure indicates the last two bus cycles of the command sequence.
Figure 19. Alternate CE# Controlled Write Operation Timings
May 9, 2006 Am29F004B_00_E4
Am29F004B