3.3.Definition of Viewing Angle and Optimum Viewing Area
・Point ● shows the point where contrast ratio is measured. : θ= 0 ゚, φ=-゚
・Driving condition : 1/16 Duty, 1/5 Bias, VD=7.8V, fF=70Hz
90 ゚
135 ゚
45 ゚
180 ゚
φ
θ
10 20 30 40 50 (φ= 0 ゚)
θ
180 ゚
225 ゚
・Area
270 ゚
shows typ. CR≧2
315 ゚
270 ゚
90 ゚
φ
0゚
3.4.System Block Diagram
Photometer
#1980A WB
Temperature Chamber
Rotation Table (θ,φ)
φ
LCD
Optical Fiber
θ
Computer
Control Unit &
Waveform Generator
Halogen bulb
DMC40202NJ-SLY-D (AK) No.99-0180
OPTREX CORPORATION
OPTREX