DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TQ2H-L-12-Z 查看數據表(PDF) - Panasonic Corporation

零件编号
产品描述 (功能)
生产厂家
TQ2H-L-12-Z Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
TQ
2) 1 coil latching
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
75%V or less of
nominal voltage*
(Initial)
3) 2 coil latching
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
75%V or less of
nominal voltage*
(Initial)
12V DC
24V DC
*Pulse drive (JIS C 5442-1986)
Reset voltage
(at 20°C 68°F)
75%V or less of
nominal voltage*
(Initial)
Nominal operating
current
(at 20°C 68°F)
46.9mA
23.3mA
15.6mA
14mA
11.7mA
7.8mA
5.8mA
4.2mA
Coil resistance
[±10%] (at 20°C 68°F)
32
128.6
289.3
357
514
1,157
2,057
5,760
Nominal operating
power
70mW
100mW
Max. applied voltage
(at 20°C 68°F)
150%V of
nominal voltage
Reset voltage
(at 20°C 68°F)
75%V or less of
nominal voltage*
(Initial)
Nominal operating
current
(at 20°C 68°F)
Set coil Reset coil
93.8mA 93.8mA
46.7mA 46.7mA
31mA
31mA
28.1mA 28.1mA
23.3mA 23.3mA
15.5mA 15.5mA
11.7mA 11.7mA
8.3mA
8.3mA
Coil resistance
[±10%] (at 20°C 68°F)
Set coil
16
64.3
145
178
257
579
1,028
2,880
Reset coil
16
64.3
145
178
257
579
1,028
2,880
Nominal operating
power
Set coil Reset coil
140mW 140mW
200mW 200mW
Max. applied voltage
(at 20°C 68°F)
150%V of
nominal voltage
2. Specifications
Characteristics
Item
Specifications
Contact
Arrangement
Initial contact resistance, max.
Contact material
2 Form C
Max. 75 m(By voltage drop 6 V DC 1A)
AgNi type+Au clad
Nominal switching capacity
2 A 30 V DC, 0.5 A 125 V AC (resistive load)
Max. switching power
60 W (DC), 62.5 VA (AC) (resistive load)
Max. switching voltage
220 V DC, 125 V AC
Rating
Max. switching current
Min. switching capacity (Reference value)*1
Nominal operating
power
Single side stable
1 coil latching
2 coil latching
Insulation resistance (Initial)
2A
10µA 10mV DC
140 mW (1.5 to 12 V DC), 200 mW (24 V DC), 300 mW (48 V DC)
70 mW (1.5 to 12 V DC), 100 mW (24 V DC)
140 mW (1.5 to 12 V DC), 200 mW (24 V DC)
Min. 1,000M(at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Electrical
characteristics
Breakdown voltage
(Initial)
Surge breakdown
voltage (Initial)
Between open contacts
Between contact and coil
Between contact sets
Between open contacts
Between contacts and coil
Temperature rise (at 20°C 68°F)
1,000 Vrms for 1 min. (Detection current: 10 mA)
1,500 Vrms for 1 min. (Detection current: 10 mA)
1,500 Vrms for 1 min. (Detection current: 10 mA)
1,500 V (10×160µs) (FCC Part 68)
2,500 V (2×10µs) (Bellcore)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)
Operate time [Set time] (at 20°C 68°F)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Mechanical
characteristics
Release time [Reset time] (at 20°C 68°F)
Shock resistance
Vibration resistance
Functional
Destructive
Functional
Destructive
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10µs.)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 5 mm
Expected life
Mechanical
Electrical
Min. 108 (at 180 cpm)
Min. 105 (2 A 30 V DC resistive), Min. 2×105 (1 A 30 V DC resistive),
Min. 105 (0.5 A 125 V AC resistive) (at 20 cpm)
Conditions
Conditions for operation, transport and storage*2
Ambient temperature:
–40°C to +85°C –40°F to +185°F, Max. –40°C to +70°C (2A) Max. –40°F to +158°F (2A);
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load)
20 cpm
Unit weight
Approx. 2 g .071 oz
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (SX relays are available for low level load switching [10V DC, 10mA max. level])
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 25).
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.