IS61LV6464
OPERATING RANGE
Range
Ambient Temperature
Commercial
0°C to +70°C
Industrial
–40°C to +85°C
VCC
3.3V +10%, –5%
3.3V +10%, –5%
VCCQ
2.375V min., 3.465V max.
2.375V min., 3.465V max.
DC ELECTRICAL CHARACTERISTICS(1) (Over Operating Range)
Symbol Parameter
Test Conditions
VOH
Output HIGH Voltage
IOH = –1.0 mA
VOL
Output LOW Voltage
IOL = 1 mA
VIH
Input HIGH Voltage
VIL
Input LOW Voltage
ILI
Input Leakage Current
GND < VIN < VCCQ(2)
Com.
Ind.
ILO
Output Leakage Current
GND < VOUT < VCCQ, OE = VIH Com.
Ind.
Min.
Max.
Unit
2.0
—
V
—
0.4
V
1.7 VCCQ + 0.3 V
–0.3
0.8
V
–2
2
µA
–10
10
–2
2
µA
–10
10
POWER SUPPLY CHARACTERISTICS (Over Operating Range)
Symbol Parameter
Test Conditions
-100
Typ. Max.
-6
Typ. Max.
-7
Typ. Max.
-8
Typ. Max. Unit
ICC
AC Operating
Device Selected,
Com. 210 250
Supply Current
All Inputs = VIL or VIH
OE = VIH,
Ind. — —
Cycle Time > tKC min.
190 200
200 220
160 170
170 190
140 150 mA
160 170 mA
ISB1 Standby Current Device Deselected,
Com. 45 70
TTL Inputs
VCC = Max.,
Ind. — —
All Inputs = VIH or VIL
CLK Cycle Time > tKC min.
45 70
50 75
45 70
50 75
45 70 mA
50 75 mA
ISB2 Standby Current Device Deselected,
Com. 2 5
CMOS Inputs
VCC = Max.,
Ind. — —
VIN > VCC – 0.2V, or VIN < 0.2V
CLK Cycle Time > tKC min.
25
5 10
25
5 10
2 5 mA
5 10 mA
IZZ
Power-Down Mode ZZ = VCCQ, CLK Running Com. 1 5
Current
All Inputs < GND + 0.2V Ind. — —
or > VCC – 0.2V
15
2 15
15
2 15
1 5 mA
2 15 mA
Note:
1. The MODE pin has an internal pullup. ZZ pin has an internal pull-down. This pin may be a No Connect, tied to GND, or tied to
VCCQ.
2. The MODE pin should be tied to Vcc or GND. It exhibits ±10 µA maximum leakage current when tied to < GND + 0.2V
or > Vcc – 0.2V.
Integrated Circuit Solution Inc.
7
SSR010-0B