MAX6633/MAX6634/
MAX6635
12-Bit Plus Sign Temperature Sensors
with SMBus/I2C-Compatible Serial Interface
Electrical Characteristics (continued)
(VCC = +3.0V to +5.5V, TA = -55°C to +125°C, unless otherwise noted. Typical values are VCC = +3.3V, TA = +25°C, unless other-
wise noted.)
PARAMETER
SYMBOL
SMBus TIMING (Note 3) (Figures 1, 2, and 3)
Serial Clock Frequency
fSCL
Bus Free Time Between STOP
and START Condition
tBUF
CONDITIONS
MIN TYP MAX UNITS
10
100
kHz
4.7
µs
START Condition Setup Time
4.7
µs
Repeat START Condition Setup
Time
tSU:STA 90% to 90%
4.7
µs
START Condition Hold Time
tHD:STA 10% of SMBDATA to 90% of SMBCLK
4
STOP Condition Setup Time
tSU:STO 90% of SMBCLK to 10% of SMBDATA
4
Data Setup Time
tSU:DAT 90% of SMBDATA to 10% of SMBCLK
250
Data Hold Time (Note 4)
tHD:DAT
300
Receive SCL/SDA Rise Time
tR
SCL/SDA Fall Time (Note 4)
tF
Clock Low Period
tLOW
10% to 10%
4.7
Clock High Period
tHIGH 90% to 90%
4
SMBus Timeout
25
µs
µs
ns
ns
1
µs
300
ns
µs
µs
48
ms
Note 1: Guaranteed by design and characterization.
Note 2: Peak operating current measured during conversion. See Figure 4.
Note 3: Guaranteed by design, not production tested.
Note 4: A master device must provide a hold time of at least 300ns for the SDA signal in order to bridge the undefined region of
SCL’s falling edge.
www.maximintegrated.com
Maxim Integrated │ 3