ABSOLUTE MAXIMUM RATINGS
High Voltage Supply (internal regulators disabled) ○ ○ ○75V
High Voltage Supply (using internal regulators) ○ ○ ○ ○ ○ 55V
Current Command Input ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ±13.5V
Logic Inputs ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ -0.2V to REFOUT
±15VOUT External Load
±25 mA
○
○
○
○
○
○
○
○
○
○
○
REFOUT External Load ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 15 mA
E/A OUT External Load ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 5 mA
Clock SYNC Input ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ -0.2V to +15V
Continuous Output Current ○ ○ ○ ○ ○ ○ ○ ○ ○ 30 Amps
Peak Output Current
41 Amps
○
○
○
○
○
○
○
○
○
○
○
○
○
RθJC Thermal
Resistance
(Output
Switches)
○
○
○
○
○
1○ .5°C/W
RθJC Thermal
Resistance
(Regulator)
○
○
○
○
○
○
○
○
○
○
○ 9°C/W
TST Storage Temperature Range ○ ○ ○ ○ ○ ○-65°C to +150°C
TLD Lead Temperature Range ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ +○ 300°C
(10 Seconds)
TC Case Operating Temperature ○ ○ ○ ○ ○ -○55°C to +125°C
TJ Junction Temperature ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ +○ 150°C
ELECTRICAL SPECIFICATIONS
Parameter
Test Conditions
Group A
MSK 4362(H) 3
Subgroup Min. Typ. Max.
MSK 4362 2
Min. Typ. Max.
Units
INPUT CURRENT
+15 VIN
-15 VIN
Output PWM'ing
Current Command=0 Volts
1
-
68
85
-
1
-
30
40
-
PWM
Clock Free Running Frequency
4
21
22
23
20
5,6 18.7 22 25.3
-
CLOCK SYNC INPUT
VIL 1
-
-
-
2.5
-
VIH 1
-
12.5
-
-
12.5
Duty Cycle 1
-
10
-
90
10
SYNC Frequency 1
- Clock +0 - Clock +3 Clock +0
REGULATORS
+15 VOUT
-15 VOUT
REFOUT
-15 VOUT Ripple
25mA Load 6
25mA Load 6
15mA Load
50mA Load
1,2,3 14.25
-
15.75 14.25
1,2,3 -14.25 - -15.75 -14.25
1,2,3 5.82
-
6.57 5.82
4
-
-
250
-
LOGIC INPUTS
(Hall A,B,C,Brake,60°/120°,DIS)
VIL 1
-
-
-
0.8
-
VIH 1
-
3.0
-
-
3.0
ANALOG SECTION
Current Command Input Range 1
-
-13.5
- +13.5 -13.5
Current Command Input Current 1
-
-
-
1.5
-
Transconductance 8
4
2.70
3
3.30 2.55
5,6 2.55
3
3.45
-
Offset Current
Current Command=0Volts
1
-25
2,3
-50
0
0
25
50
-50
-
Current Monitor 8
4
0.300 0.33 0.367 0.280
5,6 0.280 0.33 0.380
-
Current Monitor Voltage Swing 1
5mA Load
-
-12
-
+12 -12
ERROR AMP
E/A OUT Swing 1
Slew Rate 1
Gain Bandwidth Product 1
5mA Load
-
-12
-
+12 -12
-
6.5
8
-
6.5
-
6.5
-
-
Large Signal Voltage Gain 1
-
175 275
-
175
OUTPUT SECTION 1
Voltage Drop Across Bridge (1 Upper & 1 Lower) 1
30 AMPS
-
-
-
1
-
Voltage Drop Across Bridge (1 Upper & 1 Lower) 1 30 AMPS @ 150°c Junction
-
-
-
1.83
-
Leakage Current 1 7
All switches off, V+=60V, 150°C Junction
-
-
-
750
-
Diode VSD 1
-
-
-
2.6
-
trr 1
-
-
280
-
-
Dead Time 1
-
-
2
-
-
NOTES:
1 Guaranteed by design but not tested. Typical parameters are representative of actual device performance but are for reference only.
2 Industrial grade devices shall be tested to subgroups 1 and 4 unless otherwise specified.
3 Military grade devices ("H" Suffix) shall be 100% tested to Subgroups 1, 2, 3 and 4.
4 Subgroups 5 and 6 testing available upon request.
5 Subgroup 1, 4 TA = TC = +25°C
2, 5 TA = TC =+125°C
3, 6 TA = TC = -55°C
6 Maximum power dissipation must be limited according to voltage regulator power dissipation.
7 Hybrid powered by external ±15V supplies.
8 Measurements do not include offset current at 0V current command.
2
68
30
22
-
-
-
-
-
-
-
-
-
-
-
-
-
3
-
0
-
0.33
-
-
-
8
6.5
275
-
-
-
-
280
2
85
mA
40
mA
24
KHz
-
KHz
2.5 VOLTS
- VOLTS
90
%
Clock +3 KHz
15.75
-15.75
6.57
250
VOLTS
VOLTS
VOLTS
mV
0.8 VOLTS
- VOLTS
+13.5
1.5
3.45
-
50
-
0.380
-
+12
VOLTS
mA
A/V
A/V
mA
mA
V/A
V/A
VOLTS
+12
-
-
-
VOLTS
V/µSec
MHz
V/mV
1
1.83
750
2.6
-
-
VOLTS
VOLTS
µA
VOLTS
nSec
µSec
Rev. F 6/00