X9015
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias .........................–65°C to +135°C
Storage Temperature ..............................–65°C to +150°C
Voltage on CS, INC, U/D, VH, VL and VCC
with Respect to VSS.................................. –1V to +7V
∆V = |VH–VL| ................................................................. 5V
Lead Temperature (Soldering 10 seconds)............. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
listed in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Commercial
0°C
+70°C
Industrial
–40°C
+85°C
Supply Voltage (VCC)
X9015
X9015-2.7
Limits
5V ±10%
2.7V to 5.5V
POTENTIOMETER CHARACTERISTICS (Over recommended operating conditions unless otherwise stated.)
Symbol
RTOTAL
VVH
VVL
RW
RW
IW
CH/CL/CW
Parameter
End to End Resistance Variation
VH Terminal Voltage
VL Terminal Voltage
Power Rating
Wiper Resistance
Wiper Resistance
Wiper Current
Noise
Resolution
Absolute Linearity(1)
Relative Linearity(2)
RTOTAL Temperature Coefficient
Ratiometric Temperature Coefficient
Potentiometer Capacitances
Min.
–20
0
0
-1
-0.2
Limits
Typ. Max. Units
+20 %
VCC
V
VCC
V
10 mW
200 400 Ω
400 1000 Ω
±1 mA
-120
dBV
3
%
+1 MI(3)
+0.2 MI(3)
±300
ppm/°C
±20 ppm/°C
10/10/25
pF
Test Conditions/Notes
RTOTAL ≤ 50KΩ
IW = 1mA, VCC = 5V
IW = 1mA, VCC = 2.7V
Ref: 1kHz
Vw(n)(actual) – Vw(n)(expected)
Vw(n+1) – [Vw(n)+MI]
See circuit #3
Notes:
(1) Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage
= (Vw(n)(actual) – Vw(n)(expected)) = ±1 Ml Maximum.
(2) Relative Linearity is a measure of the error in step size between taps = VW(n+1) – [Vw(n) + Ml] = ±0.2 Ml.
(3) 1 Ml = Minimum Increment = RTOT/31.
(4) Typical values are for TA = 25°C and nominal supply voltage.
(5) This parameter is periodically sampled and not 100% tested.
4