Parameter Measurement Information
74LVC1G06
SINGLE INVERTER BUFFER/DRIVER WITH
OPEN DRAIN OUTPUT
TEST
tPLZ (see Notes D and E)
tPZL(see Notes D and F)
Condition
Vload
Vload
Vcc
1.8V±0.15V
2.5V±0.2V
3.3V±0.3V
5V±0.5V
Inputs
VI
tr/tf
VCC
≤2ns
VCC
≤2ns
3V
≤2.5ns
VCC
≤2.5ns
VM
VCC/2
VCC/2
1.5V
VCC/2
VLOAD
2 X VCC
2 X VCC
6V
2 X VCC
CL
30pF
30pF
50pF
50pF
RL
1KΩ
500Ω
500Ω
500Ω
V∆
0.15V
0.15V
0.3V
0.3V
Voltage Waveform
Pulse Duration
Voltage Waveform
Propagation Delay Times
Figure 1. Load Circuit and Voltage Waveforms
Notes:
A. Includes test lead and test apparatus capacitance.
B. All pulses are supplied at pulse repetition rate ≤ 10 MHz
C. The inputs are measured one at a time with one transition per measurement.
D. For the open drain device tPLZ and tPZL are the same as tPD
E. tPZL is measured at VM.
F. tPLZ is measured at VOL +V∆
74LVC1G06
Document number: DS32272 Rev. 2 - 2
7 of 13
www.diodes.com
October 2010
© Diodes Incorporated