Philips Semiconductors
Table 10: Measurement points
Supply voltage Input
VCC
1.65 V to 1.95 V
2.3 V to 2.7 V
2.7 V
VM
0.5 × VCC
0.5 × VCC
1.5 V
3.0 V to 3.6 V
1.5 V
4.5 V to 5.5 V
0.5 × VCC
VI
VCC
VCC
2.7 V
2.7 V
VCC
74LVC3G07
Triple buffer with open-drain output
Output
VM
0.5 × VCC
0.5 × VCC
1.5 V
1.5 V
0.5 × VCC
VX
VOL + 0.15 V
VOL + 0.15 V
VOL + 0.3 V
VOL + 0.3 V
VOL + 0.3 V
VCC
VI
PULSE
GENERATOR
VO
D.U.T.
RT
VEXT
RL
CL
RL
mna616
Test data are given in Table 11.
Definitions for test circuit:
RL = Load resistor.
CL = Load capacitance including jig and probe capacitance.
RT = Termination resistance should be equal to the output impedance Zo of the pulse
generator.
Fig 7. Load circuitry for switching times
Table 11: Test data
Supply voltage Input
VCC
1.65 V to 1.95 V
2.3 V to 2.7 V
2.7 V
VI
VCC
VCC
2.7 V
3.0 V to 3.6 V
2.7 V
4.5 V to 5.5 V
VCC
tr = tf
≤ 2.0 ns
≤ 2.0 ns
≤ 2.5 ns
≤ 2.5 ns
≤ 2.5 ns
Load
CL
30 pF
30 pF
50 pF
50 pF
50 pF
RL
1 kΩ
500 Ω
500 Ω
500 Ω
500 Ω
VEXT
tPZL, tPLZ
2 × VCC
2 × VCC
6V
6V
2 × VCC
9397 750 14542
Product data sheet
Rev. 03 — 01 February 2005
© Koninklijke Philips Electronics N.V. 2005. All rights reserved.
8 of 14