NXP Semiconductors
74LVC3G06
Triple inverter with open-drain output
8. Limiting values
Table 5. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol
Parameter
Conditions
Min
Max
Unit
VCC
supply voltage
IIK
input clamping current
VI < 0 V
VI
input voltage
IOK
output clamping current
VO < 0 V
VO
output voltage
Active mode
Power-down mode
−0.5
+6.5
V
−50
-
mA
[1] −0.5
+6.5
V
−50
-
mA
[1] −0.5
+6.5
V
[1][2] −0.5
+6.5
V
IO
ICC
IGND
Tstg
Ptot
output current
supply current
ground current
storage temperature
total power dissipation
VO = 0 V to 6.5 V
Tamb = −40 °C to +125 °C
-
50
mA
-
100
mA
−100
-
mA
−65
+150
°C
[3] -
250
mW
[1] The minimum input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] When VCC = 0 V (Power-down mode), the output voltage can be 5.5 V in normal operation.
[3] For TSSOP8 and VSSOP8 packages: above 110 °C the value of Ptot derates linearly at 8.0 mW/K.
For XSON8, XSON8U and XQFN8U packages: above 118 °C the value of Ptot derates linearly with 7.8 mW/K.
9. Recommended operating conditions
Table 6.
Symbol
VCC
VI
VO
Operating conditions
Parameter
supply voltage
input voltage
output voltage
Tamb
Δt/ΔV
ambient temperature
input transition rise and fall rate
Conditions
Active mode
Power-down mode; VCC = 0 V
VCC = 1.65 V to 2.7 V
VCC = 2.7 V to 5.5 V
Min
Max
Unit
1.65
5.5
V
0
5.5
V
0
5.5
V
0
5.5
V
−40
+125
°C
-
20
ns/V
-
10
ns/V
74LVC3G06
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 8 — 9 August 2010
© NXP B.V. 2010. All rights reserved.
5 of 21