ADM1034
Bit Name
Speed
1
Boost Disable
0
SW Reset
R/W Description
temperature between the two thresholds. Default = 1 = Linear.
R/W Set bit to 1 to prevent the fans from being boosted if either THERM temperature or THERM timer
limits are exceeded. Under these conditions, the fan runs at the previously calculated speed. Default
= 0.
R/W Set this bit to 1 to reset the ADM1034 registers to their default values, excluding the limit registers,
offset registers, and look-up table registers. This bit self-clears. Default = 0.
Table 38. Register 0x03, Configuration Register 3, Power-On Default= 0x44, Lock = Y, SW Reset = Y
Bit
Name
R/W Description
<7:4> #Poles Fan 2
R/W Write the number of poles on Fan 2 to this register. power-on default = 4 poles = 100. This should
always be an even number, because there cannot be an odd number of poles in a fan.
<3:0> #Poles Fan 1 1
R/W Write the number of poles in Fan 1 to this register. power-on default = 4 poles = 100. This should
always be an even number, because there cannot be an odd number of poles in a fan.
Table 39. Register 0x04, Configuration Register 4, Power-On Default = 0x00, Lock = Y, SW Reset = Y
Bit
Name
R/W Description
7
FAN_FAULT/REF
R/W This bit sets the function for Pin 8. 0 = Default = FAN_FAULT output (THERM input
is CMOS). 1 = Reference input for THERM.
<6:4> THERM % Time Window
R/W These bits set the time window over which THERM % is calculated.
000 = 0.25 second
001 = 0.5 second
010 = 1 second
011 = 2 seconds
100 = 4 seconds
101 = 8 seconds
110 = 8 seconds
111 = 8 seconds
3
XOR Test
R/W Set this bit to 1 to enable the XOR connectivity test.
2
Enable Remote 2 THERM Events R/W This bit enables THERM assertions as an output. Functions when the THERM timer
is enabled and the Remote 2 temperature exceeeds its THERM limit.
1
Enable Remote 1 THERM Events R/W This bit enables THERM assertions as an output. Functions when the THERM timer
is enabled and the Remote 1 temperature exceeeds its THERM limit.
0
Enable Local THERM Events
R/W This bit enables THERM assertions as an output. Functions when the THERM timer
is enabled and the local temperature exceeeds its THERM limit.
Table 40. Register 0x05, Conversion Rate Register, Power-On Default = 0x07, Lock = Y, SW Reset = Y
Bit
Name
R/W Description
7
Res
R
This bit is reserved for future use. Do not write to this bit.
<6:4> Res
R
Reserved.
<3:0> Conversion Rate
R/W These four bits set the conversion rate of the ADM1034. Changing these bits does not update the
conversion rate until the start of the next round robin.
0000 = 0.0625 conversions/second
0001 = 0.125 conversions/second
0010 = 0.25 conversions/second
0011 = 0.5 conversions/second
0100 = 1 conversion/second
0101 = 2 conversions/second
0110 = 4 conversions/second
0111 = 8 conversions/second = default
1000 = 16 conversions/second
1001 = 32 conversions/second
1010 = 64 conversions/second
Rev. 0 | Page 33 of 40