ADuM1230
PACKAGE CHARACTERISTICS
Table 2.
Parameter
Symbol
Min
Typ
Max
Unit
Test Conditions
Resistance (Input-to-Output)1
RI-O
Capacitance (Input-to-Output)1
CI-O
1012
Ω
2.0
pF
f = 1 MHz
Input Capacitance
CI
4.0
pF
IC Junction-to-Ambient Thermal Resistance θJCa
76
°C/W
1 The device is considered a two-terminal device: Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
REGULATORY INFORMATION
The ADuM1230 is approved by the organizations listed in Table 3.
Table 3.
UL 1
Recognized under UL1577 component recognition program
E 1 In accordance with UL1577, each ADuM1230 is proof tested by applying an insulation test voltage ≥ 3000 V rms for one second (current leakage detection limit = 5 μA).
INSULATION AND SAFETY-RELATED SPECIFICATIONS
T Table 4.
Parameter
E Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
L Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Symbol
L(I01)
L(I02)
CTI
Value
2500
7.7 min
8.1 min
0.017 min
>175
IIIa
Unit
V rms
mm
mm
mm
V
Conditions
1 minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
O RECOMMENDED OPERATING CONDITIONS
Table 5.
S Parameter
Operating Temperature
Input Supply Voltage1
Output Supply Voltages1
B Input Signal Rise and Fall Times
Common-Mode Transient Immunity, Input-to-Output2
Common-Mode Transient Immunity, Between Outputs2
O Transient Immunity, Supply Voltages2
Symbol
TA
VDD1
VDDA, VDDB
Min
Max
−40
+105
4.5
5.5
12
18
100
−50
+50
−50
+50
−50
+50
Unit
°C
V
V
ns
kV/μs
kV/μs
kV/μs
1 All voltages are relative to their respective ground.
2 See the Common-Mode Transient Immunity section for transient diagrams and additional information.
Rev. B | Page 4 of 12