AZ2100
UL/CUR File E44211 Approved Contact Ratings
Load Type
Cycles
Volts
Form A Form B
(NO) (NC)
Form C
NO
NC
General Purpose
100,000 125 or 240 VAC 30 A
15 A
30 A 15 A
(Inductive)
30,000
277 VAC
30 A
30 A
30 A 30 A
Resistive
100,000 125 or 240 VAC 30 A
15 A
30 A 15 A
100,000
30 VDC
20 A
10 A
20 A 10 A
100,000
277 VAC
20 A
—
—
—
100,000 *
240 VAC
15 A
—
—
—
6,000
250 VAC
40 A
—
40 A
—
Ballast
6,000
125, 240 or
277 VAC
6A
3A
6A
3A
Pilot Duty
6,000
125 VAC
800 VA 290 VA 800 VA 290 VA
30,000
125 VAC
800 VA
—
690 VA —
100,000
125 VAC
690 VA
—
470 VA 275 VA
6,000
240 VAC
1152 VA 768 VA 1152 VA 768 VA
100,000
277 VAC
764 VA
—
764 VA —
Motor Load
6,000
125 VAC
1 HP
1/4 HP
1 HP 1/4 HP
6,000***
240 VAC
3 HP
1 HP
2 HP 1 HP
30,000
125 VAC
1 HP
—
1 HP
—
Definite Purpose
100,000 125 or 277 VAC 3/4 HP
—
3/4 HP
—
30,000 **
120 VAC
82.8 LRA — 82.8 LRA —
13.8 FLA — 13.8 FLA —
30,000
125 VAC
96 LRA 33 LRA 60 LRA 33 LRA
30 FLA 10 FLA 20 FLA 10 FLA
30,000 **
125 VAC
60 LRA 30 LRA 60 LRA 30 LRA
20 FLA 12 FLA 20 FLA 12 FLA
(LRA-Locked Rotor) 100,000
125 VAC
82.8 LRA — 82.8 LRA —
27 FLA
—
27 FLA —
(FLA-Full Load)
30,000
240 VAC
80 LRA 33 LRA 60 LRA 33 LRA
30 FLA 10 FLA 20 FLA 10 FLA
30,000 **
240 VAC
41.4 LRA — 41.4 LRA —
6.9 FLA
—
6.9 FLA —
100,000
277 VAC
60 LRA
—
60 LRA —
20 FLA
—
20 FLA —
Tungsten
6,000
6,000
6,000
6,000
125 VAC
240 VAC
120 VAC
240 VAC
15A
—
15A
3A
5A
—
5A
3A
—
3A
—
—
—
3A
—
—
TV–5
25,000
120 VAC
TV–5
—
TV–5 TV–3
TV–3
25,000
120 VAC
—
TV–3
—
TV–3
* Ambient temperature 96°C (208°F) max. sealed and 105°C (221°F) unsealed.
** Ambient temperature 85°C (185°F) max. sealed and unsealed.
*** Ambient temperature 65°C (149°F) max. sealed and unsealed.
Maximum Switching Capacity
40
NO
30
NC
20
10
8
6
AC RESISTIVE
5
LOAD
4
3
DC RESISTIVE
LOAD
2
1
10
20
30 40 60 80 100
200 300
VOLTAGE
Coil Temperature Rise
180
160
140
120
100
80
30A
60 25A
40 20A
15A
20 0A
0
40%
60% 80%
100% 120% 140% 160% 180% 200%
Percent of Nominal Coil Voltage (at 20˚C)