Up to 140 °C
Specifications and characteristics in brief
Rated voltage VR
Surge voltage VS
Rated capacitance CR
Capacitance tolerance
Dissipation factor tan δ
(20 °C, 120 Hz)
Useful life
140 °C, VR, IAC,R
Requirements
Voltage endurance test
140 °C, VR
Post test requirements
Vibration resistance test
IEC climatic category
Sectional specification
160 ... 350 V DC
1.1 VR
3.3 ... 100 µF
±20% M
VR ≤ 250 V DC: tan δ = 0.20
VR ≥ 350 V DC: tan δ = 0.25
> 1000 h
∆C/C
tan δ
Ileak
≤ ±35% of initial value
≤ 3 times initial specified limit
≤ initial specified limit
1000 h
∆C/C ≤ ±30% of initial value
tan δ ≤ 2 times initial specified limit
Ileak
≤ initial specified limit
To IEC 60068-2-6, test Fc:
Displacement amplitude 0.75 mm, frequency range 10 ... 2000 Hz,
acceleration max. 20 g, duration 3 × 2 h.
Capacitor rigidly clamped by the aluminum case.
To IEC 60068-1:
VR ≤ 250 V: 40/140/56 (40 °C/+140 °C/56 days damp heat test)
VR ≥ 350 V: 25/140/56 (25 °C/+140 °C/56 days damp heat test)
IEC 60384-4
Please read Cautions and warnings and
Important notes at the end of this document.