CXA2096N
Electrical Characteristics
(Ta = 25°C, VCC1, 2, 3 = 3V)
Item
Symbol
Conditions
Min. Typ. Max. Unit
PS = OFF
Current (PS indicates IDC
consump Power Save)
-tion
PS = ON IDP
AGCCONT = 1.5V, open between VRT and VRB
PS = 3V, ICONT = 3V
25.1
37.1
49.0
mA
PS = 0V
0 1.8 4.2
Maximum A CONT DIN = 1µs, 20mVp-p pulse
gain
max.
AGCCONT = 3V, ICONT = 3V
28.5 31.3 —
Minimum A CONT DIN = 1µs, 500mVp-p pulse
gain
min.
AGCCONT = 1.5V, ICONT = 3V
— –0.8 1.4 dB
AGC
Range of gain
variance
AGC G
A CON max. – A CON min.
Dynamic
range
maximum
AGCmax. AGCCONT = 3V
D
DRVOUT output signal at saturation level
Dynamic
range
typical
AGCTYP. AGCCONT = 2V
D
DRVOUT output signal at saturation level
27.1 32.1 —
800 970 —
mV
900 960 —
Offset high
CAOF
high
OFFSET = 1.5V
80 98 —
DRV
Offset low
CAOF
low
OFFSET = 3.0V
—
2
5 mV
Offset
preset
CAOF
pre
OFFSET = 0V
25 34 40
VRT DC
level
VRTO With a 400Ω load
2300 2340 2400
REF
VRB DC
level
VRBO With a 400Ω load
1300 1353 1400 mV
VRT – VRG ∆VR
With a 400Ω load
950 988 1050
BLK Offset
BLKOF BLKOF (PBLK = 3V) – BLKOF (PBLK = 0V) –15 9 30 mV
SH3
Dynamic
range
SH3 D
DIN = 1µs, 1Vp-p pulse
600 790 — mV
–7–