3. DETAILED DESCRIPTION
3.1 DATA INPUT AND OUTPUTS
Data enters and exits the device synchronous to the rising
edge of PCLK_IN as shown in Figure 1.
3.2 INPUT BLANKER
Data words entering the GS1511 can be dynamically set to
Luma and Chroma blanking levels if desired as shown in
Figure 3. Blanking is applied to both the LUMA and
CHROMA channels simultaneously.
PCLK_IN
DATA_IN
DATA
DATA
DATA
DATA
DATA
DATA_OUT
PCLK_IN
DATA_IN[19:0]
RSTLN
n Frames
DATA
tSU
tIH
Fig. 1 Synchronous I/O Timing
tOH
tOD
DATA
3FF
000
000
XYZ
(EAV ID)
LN0
LN1
EAV For Line#1
Line#1 Inserted
Here
Transistion From Low To High Can Happen at Any Point
Fig. 2 RSTLN Timing
PCLK_IN
DATA_IN[19:0]
BLANK
WORD
X
WORD
X+1
WORD
X+2
WORD
X+3
WORD
X+4
Data To Be Blanked
WORD
X+6
WORD
X+7
WORD
X+8
Fig. 3 Timing of Dynamic Data Blanking
PCLK_IN
DATA_IN[19:10]
(LUMA)
DATA_IN[9:0]
(CHROMA)
H
V
F
3FF
000
000
XYZ
(EAV ID)
YLN
0
3FF
000
000
XYZ
(EAV ID)
CLN
0
Fig. 4 HVF Input Timing
3FF
000
000
XYZ
(SAV ID)
3FF
000
000
XYZ
(SAV ID)
GENNUM CORPORATION
8 of 9