LTC6912
PI FU CTIO S
AGND: Analog Ground. The AGND pin is at the midpoint of
an internal resistive voltage divider, developing a potential
halfway between the V+ and Vpins. In normal operation,
the AGND pin has an equivalent input resistance of nomi-
nally 50k (Figure 1). In order to reduce the quiescent
supply current in hardware shutdown (SHDN pin pulled to
V+, GN-16 only), the equivalent series resistance of this
pin significantly increases (to a value on the order of
800kwith 5V supplies, but is highly supply voltage,
temperature, and process dependent). AGND is the
noninverting input to both the internal channel A and
channel B amplifiers. This makes AGND the ground refer-
ence voltage for the INA, INB, OUTA, and OUTB pins.
Recommended analog ground plane connection depends
on how power is applied to the LTC6912-X (See Figures 2,
3, and 4). Single power supply applications typically use
Vfor the system signal ground. The analog ground plane
in single-supply applications should therefore tie to V,
and the AGND pin should be bypassed to this ground plane
by a high quality capacitor of at least 0.1µF (Figure 2). The
AGND pin provides an internal analog reference voltage at
half the V+ supply voltage. Dual supply applications with
symmetrical supplies (such as ±5V) have a natural system
ground plane potential of zero volts, in which the AGND pin
can be directly tied to, making the zero volt ground plane
the input and output reference voltage for the LTC6912-X
(Figure 3). Finally, if dual asymmetrical power supplies are
used, the supply ground is still the natural ground plane
voltage. To maximize signal swing capability with an
asymmetrical supply, however, it is often desirable to refer
the LTC6912-X’s analog input and output to a voltage
equidistant from the two supply rails V+ and V. The AGND
pin will provide such a potential when open-circuited and
bypassed with a capacitor (Figure 4). In noise sensitive
applications where AGND does not tie directly to a ground
plane, as in Figures 2 and 4, it is important to AC-bypass
the AGND pin. Otherwise channel to channel isolation is
degraded, and wideband noise will enter the signal path
from the thermal noise of the internal voltage divider
resistors which present a Thévenin equivalent resistance
of approximately 50k. This noise can reduce SNR by at
least 15dB at high gain settings. An external capacitor
from AGND to the ground plane, whose impedance is well
below 50kat frequencies of interest, will filter and
suppress this noise. A 0.1µF high quality capacitor is
effective for frequencies down to 1kHz. Larger capacitors
will extend this suppression to lower frequencies. This
issue does not arise in dual supply applications because
the AGND pin ties directly to ground. In applications
requiring an analog ground reference other than half the
total supply voltage, the user can override the built-in
analog ground reference by tying the AGND pin to a
reference voltage with the AGND voltage range specified in
the Electrical Characteristics Table. The AGND pin will load
the external reference with approximately 50kreturned
to the half-supply potential. AGND should still be capaci-
tively bypassed to a ground plane as noted above. Do not
connect the AGND pin to the Vpin.
V+
2
REFERENCE
1
0.1µF 2
3
4
5
6
SERIAL 7
INTERFACE 8
ANALOG GROUND PLANE
16
LTC6912-X 15
14
13
12
11
10
9
0.1µF
V+
SINGLE-POINT
SYSTEM GND
DIGITAL GROUND PLANE
6912 F02
Figure 2. Single Supply Ground Plane Connection
1
2
3
4
5
6
SERIAL 7
INTERFACE 8
ANALOG GROUND PLANE
LTC6912-X
16
15 0.1µF
14 V
13 0.1µF
12 V+
11
10
9
SINGLE-POINT
SYSTEM GND
DIGITAL GROUND PLANE
6912 F03
Figure 3. Symmetrical Dual Supply Ground Plane Connection
6912fa
17