DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX849ESE 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
生产厂家
MAX849ESE Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
1-Cell to 3-Cell, High-Power,
Low-Noise, Step-Up DC-DC Converters
OUT
2.25V
ON1
ON2
REF
GND
CLK/SEL
FB
POKIN
AINSEL
AIN1
AIN2
1.25V
ON
RDY
REF
FEEDBACK
AND
POWER-GOOD
SELECT
FEEDBACK
START-UP
OSCILLATOR
EN
Q
MAX848/MAX849
POUT
D
Q
PCH
0.25
EN
EN
300kHz
OSCILLATOR
OSC
Q
PFM/PWM
MODE
PFM/PWM
CONTROLLER
EN
ADC
NCH
0.13
N
LX
PGND
POK
DATA
Figure 1. Functional Diagram
_______________Detailed Description
The MAX848/MAX849 combine a switching regulator,
N-channel power MOSFET, P-channel synchronous
rectifier, precision reference voltage, power-good indi-
cator, and battery voltage monitor, all in a single mono-
lithic device. The MAX848/MAX849 are powered
directly from the output. The output voltage is factory
preset to 3.3V or adjustable from 2.7V to 5V with exter-
nal resistors (Dual Mode™ operation). These devices
start from a low 1V input voltage and remain opera-
tional down to 0.7V. The MAX848/MAX849 operate with
either one to three NiCd/NiMH cells or one Li-Ion cell.
At power-up, an internal low-voltage oscillator drives
the N-channel power switch, and the output voltage
slowly builds up. The oscillator has a 25% nominal duty
cycle to prevent current build-up in the inductor. An
output voltage in excess of the nominal 2.25V lockout
voltage activates the error comparator and internal tim-
ing circuitry. The device resumes operation in either
pulse-frequency-modulation (PFM) low-power mode or
pulse-width-modulation (PWM) low-noise mode, select-
ed by the logic control, CLK/SEL. Figure 2 shows the
standard application circuit for the MAX849 configured
in the high-power PWM mode.
On/Off Control
The MAX848/MAX849 are turned on or off by logic
input pins ON1 and ON2 (Table 1). When ON1 = 1 or
ON2 = 0, the part is on. When ON1 = 0 and ON2 = 1,
the part is off. Both inputs have logic trip points near
0.5 x VOUT with 0.15 x VOUT hysteresis.
Table 1. On/Off Logic Control
ON1
0
0
1
1
ON2
0
1
0
1
MAX848/MAX849
On
Off
On
On
Operating Modes
The MAX848/MAX849 operate in either PFM, PWM, or
PWM synchronized to an externally applied clock sig-
nal. Table 2 lists each operating mode.
_______________________________________________________________________________________ 9