MC10H644, MC100H644
Table 2. 10H PECL DC CHARACTERISTICS (VT = VE = 5.0 V ±5%)
0°C
25°C
85°C
Symbol
Characteristic
Condition
Min Max Min Max Min Max Unit
IINH
Input HIGH Current
IINL
Input LOW Current
255
175
175 mA
0.5
0.5
0.5
VIH*
Input HIGH Voltage
VIL*
Input LOW Voltage
VE = 5.0 V
3.83 4.16 3.87 4.19 3.94 4.28 V
3.05 3.52 3.05 3.52 3.05 3.55
VBB*
Output Reference Voltage
VE = 5.0 V
3.62 3.73 3.65 3.75 3.69 3.81 V
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
Table 3. 100H PECL DC CHARACTERISTICS (VT = VE = 5.0 V ±5%)
0°C
25°C
85°C
Symbol
Characteristic
Condition
Min Max Min Max Min Max Unit
IINH
Input HIGH Current
IINL
Input LOW Current
255
175
175 mA
0.5
0.5
0.5
VIH*
Input HIGH Voltage
VIL*
Input LOW Voltage
VE = 5.0 V
3.835 4.12 3.835 4.12 3.835 4.12 V
3.19 3.525 3.19 3.525 3.19 3.525
VBB*
Output Reference Voltage
VE = 5.0 V
3.62 3.74 3.62 3.74 3.62 3.74 V
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
*PECL levels are referenced to VCC and will vary 1:1 with the power supply. The values shown are for VCC = 5.0 V.
Only corresponds to ECL Clock Inputs.
Table 4. DC CHARACTERISTICS (VT = VE = 5.0 V ±5%)
0°C
25°C
85°C
Symbol
Characteristic
Condition
Min Max Min Max Min Max Unit
IEE
Power Supply Current
ECL
VE Pin
65
65
65 mA
ICC
TTL
Total all VT pins
85
85
85 mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
Table 5. TTL DC CHARACTERISTICS (VT = VE = 5.0 V ±5%)
0°C
25°C
85°C
Symbol
Characteristic
Condition
Min Max Min Max Min Max Unit
VIH
Input HIGH Voltage
VIL
Input LOW Voltage
IIH
Input HIGH Current
VIN = 2.7 V
VIN = 7.0 V
2.0
2.0
2.0
V
0.8
0.8
0.8
20
20
20 mA
100
100
100
IIL
Input LOW Current
VOH
Output HIGH Voltage
VIN = 0.5 V
IOH = −3.0 mA
IOH = −24 mA
−0.6
−0.6
−0.6 mA
2.5
2.5
2.5
V
2.0
2.0
2.0
VOL
Output LOW Voltage
IOL = 24 mA
0.5
0.5
0.5 V
VIK
Input Clamp Voltage
IIN = −18 mA
−1.2
−1.2
−1.2 V
IOS
Output Short Circuit Current
VOUT = 0 V
−100 −225 −100 −225 −100 −225 mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
http://onsemi.com
3